Current power arrangement

The rack PDU provides distribution and surge protection. There is no UPS. A utility outage therefore stops Proxmox, TrueNAS, and the network without battery runtime or a coordinated battery-triggered shutdown.

The dedicated dashboard PC follows a separate efficiency schedule: it shuts down at midnight and schedules an RTC wake for 7:00 a.m. The always-on servers do not use that daily power schedule.

Known failure domains

FailureCurrent protection
One data disk in a mirrorZFS mirror redundancy
Accidental dataset changeZFS snapshots, depending on dataset policy
Broken application or VM-local stateDaily application exports and volume archives
Complete ZFS pool lossMonthly external copy for selected important datasets
Complete site lossNo off-site copy yet
Utility outageSurge protection only; no battery runtime
Missed service degradationDashboards exist; declarative alerts are incomplete